1006h Communication cycle period


  • CAN bus only

This object can be used to define the period (in µs) for the transmission of the SYNC telegram.

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Communication cycle period 1006h 0 Unsigned32 - - Read/Write No All